synced 2026-04-03 15:02:13 +08:00
The SSE stream termination marker string was incorrectly included in DefaultStopSequences, causing Gemini to prematurely stop generating output whenever the model produced text containing that marker. The SSE-level protocol filtering in stream_transformer.go already handles this marker correctly; it should not be a stop sequence for the model's text generation.